Document
5900-189 Completion Report for Energy Star Modular Home
ICR 200910-2060-009 · OMB 2060-0586 · Object 14202401.
Completion Report for ENERGY STAR Modular Home
CONTACT INFORMATION
a) Rater primary contact b) Rater field tester (if different from primary contact)
-
Company Name
Company Name
Address
Address
City State Zip
City State Zip
Telephone Email
Telephone Email
c) Factory d) Builder
-
Corporate Parent
Company Name
Plant name
Address
Plant City Plant State Zip
Zip
City State Zip
Telephone Fax
e) Homeowner f) Home location
-
Name
Address
Telephone
City State Zip
Was this home tested? Yes No If No, skip to question 4. Conditioned space sq. ft.:
House tightness (must fill in and check to pass)
ACH50. Measured: ______________ (must be ≤ 7.0 in CZ 1-2 | ≤ 6.0 in CZ 3-4 | ≤ 5.0 in CZ 5-7 | ≤ 4.0 in CZ 8)
DUCT TIGHTNESS (must fill in and check ONE to pass)
Duct leakage to outside at 25 pascals. Measured: ______________ (must be ≤ 4 cfm to outdoors / 100 sq. ft.)
All ducts and air handling equipment are in conditioned space and envelope leakage tests
at ≤ 3 ACH 50 or ≤ 0.25 cfm 50 per sq. ft. of building envelope.
QUALITY ASSURANCE (QA) LABEL (must check ONE to pass)
An SBRA quality assurance (QA) ENERGY STAR Modular Home Label is affixed to the home interior and signed
and dated by a factory representative This home is one of the factory’s initial three certification homes (QA label will be affixed with site label – see below)
RATER EVALUATION (check one)
PASSES: No discrepancies were identified.
FAILS: Discrepancies are described on the following sheet.
Signature of Rater: Date:
Complete all applicable items and send with a completed copy of the Inspection Checklist for ENERGY STAR Qualified Modular Homes and, if home passes, a check for $40 (or $140 if this is one of the initial three factory certification homes) to: Systems Building Research Alliance, 2109 Broadway, Suite 200, New York, NY 10023.
Description of problems/discrepancies and remediation actions
-
Item number:
_____
Discrepancy
Remediation
Item number:
_____
Discrepancy
Remediation
Item number:
_____
Discrepancy
Remediation
Item number:
_____
Discrepancy
Remediation
Energy
Star Modular Homes Rev.
| File Type | application/msword |
| File Title | 110 |
| Author | jdentz |
| Last Modified By | ctsuser |
| File Modified | 2009-09-17 |
| File Created | 2009-09-09 |